Search

Your Notifications (0)

There are currently no notifications. You're all set!

What's New

Explore recent and historical product updates for Revvity Signals' Cloud Native SaaS Software 

Collapse All

58 releases — this page expanded. Collapse

What’s New

We are delighted to release Signals BioDesign 26.8. This release introduces comprehensive sequence collection management with support for custom DNA, Protein, and Oligo collections, delivers an enhanced out-of-the-box onboarding experience for new tenants, and brings streaming pagination to large assembly grids. We have fixed several smaller bugs to improve product quality.

The following improvements are available to users, administrators, and developers on the Signals platform. Some features may require appropriate licensing and/or administrator enablement.

  • Admin defined Sequence Collections
  • Updated security policy examples and settings

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

Further Details

This section provides additional details about generally available improvements and capabilities included in Signals BioDesign 26.8. Some features may require appropriate licensing and/or administrator enablement.

Admin defined Sequence Collections

Image 1 from Signals BioDesign What's New 26.8 External.docx

To support growing enterprise organizations with distinct business units (such as Bioprocessing, Cell Line Engineering, and Protein Therapeutics), administrators can now create, organize, and govern multiple sequence collections. System sequence collections are highlighted, and collections can be created and managed from a central page.

Image 2 from Signals BioDesign What's New 26.8 External.docx

Administrators may create any number of sequence collections of type DNA, Protein, or Oligo. Access to each System or Custom collection can be controlled through the system security policy and group associations. Once configured and activated, these collections become available to the users with access granted. Note that custom collections can be inactivated or deleted, but System collections may only be inactivated.

Updated security policy examples and settings

Starting with the 26.8 release, newly provisioned Signals BioDesign tenants ship with pre-configured settings that enable licensed standard users to begin designing immediately without prerequisite setup.

All standard users on new tenants automatically receive default privileges to add, edit, delete, and export sequences. Default example security policies are permissive out-of-the-box, ensuring users have immediate access to default sequence collections and cloning tools. Administrators may enable these example policies by removing the commenting on them or use them as templates to write their own custom security policies to provide appropriate user access to collections.

What’s New

This Signals release introduces Collections in ChemDraw+ as a beta capability. A Collection is a living, editable, and searchable list of compounds, reactions, or drawings and their associated data. Built-in chemical intelligence automatically calculates intrinsic and predicted properties and supports advanced structure-aware searching and filtering. Collection data can also be imported and exported, while administrators can configure templates, properties, numbering, and user permissions in Signals Configuration. This release also includes bug fixes.

The following improvements are available for users of Signals ChemDraw. Certain features may only be available with enablement by an administrator.

ChemDraw+

  • Create lists of compounds, reactions or drawings and their associated data using Collections (beta)

Signals Configuration

  • Configure Collections system object (beta)

Signals ChemDraw users and administrators should be aware that the stand alone ChemDraw Collections application will be retired once Collections are released from beta in ChemDraw+, after which it will no longer launch. All existing Collections data will be preserved automatically and made available in ChemDraw+, so no migration or preparation is required. 

Administrators should also note that two capabilities from the stand-alone application will not be carried over to ChemDraw+:

  • PowerPoint export from configured reports, for which SD file export remains available,
  • File explorer with embedded chemical object preview.

Where existing workflows depend on these capabilities, alternative approaches such as SD file export and manual presentation creation will be required. Full details are available in the Collections are moving to ChemDraw+ announcement.

Beta Features

The following capabilities are in beta and are available for users and administrators of Signals ChemDraw upon request. Please contact your account representative or our support team if you would like access to the following features.

ChemDraw+

Create lists of compounds, reactions or drawings and their associated data using Collections

Image 1 from Signals ChemDraw What's New 26.8_October_2026.docx

Collections are a new entity available in ChemDraw+ that turn compounds, reactions, drawings, and their associated data into living, editable, and searchable lists that can evolve as work progresses. A Collection can be created from the Add New button in ChemDraw+. Each Collection displays entries and properties in a table, making chemistry and related data easier to organize, update, and find. Collections can be created inside a Notebook or as stand-alone items, with support for up to 5,000 entries.

Image 2 from Signals ChemDraw What's New 26.8_October_2026.docx

Entries can be added directly to a Collection by selecting Add Entry, which opens the ChemDraw editor for drawing a structure, reaction, or other chemical content. Once saved, the drawing is added to the Collection as a new entry. Existing entries can be reopened and updated by selecting their preview.

Entries can also be added from an existing ChemDraw+ Drawing by selecting Add to Collection in the editor. The entire drawing can be added as a single entry, or all structures or all reactions can be added as separate entries. When specific content is selected on the canvas, only that selection is added. The preferred option can be chosen by the user before adding the entries to the Collection.

Image 3 from Signals ChemDraw What's New 26.8_October_2026.docx

As entries are added, Collections become chemically intelligent lists by adding and automatically calculating selected intrinsic and predicted properties for each structure. A broad range of calculated properties are available through the Add System Properties button, including Molecular Formula, Chemical Name, Molecular Weight, Exact Mass, Canonical SMILES, LogP, and predicted pKa, among others. Calculations are also applied to existing entries when a property is added, providing consistent chemical data without manual entry.

Alongside calculated properties, editable properties can capture additional scientific data for each entry. Users can add text, number, or hyperlink columns directly to a Collection and edit values within the table using Tab and Enter for keyboard navigation.

Administrators can make additional property types available, including numbers with units, dates and times, attribute and multi-select lists, hyperlinks, and internal references. Numbers with units follow the units configured for the tenant, and significant figures are preserved as entered.

To make the data in the Collection easier to review and analyze, the table can be customized by reordering, hiding, or resizing columns and choosing whether long content wraps or is truncated. The Entry and Entry ID columns remain fixed during horizontal scrolling, and view settings are saved for the next time the Collection is opened.

Collection data can then be quickly narrowed using text search, column filters, and chemically intelligent structure filters. Applied filters appear above the table for easy review and removal. Structure filters can be added from the Entry column header using substructure, similarity, full, exact, or full-including-tautomers matching. Multiple structure filters can be combined with one another and with other active filters.

Image 4 from Signals ChemDraw What's New 26.8_October_2026.docx

Large collections of compounds can be brought into a Collection quickly using Bulk Import from the Add Entry menu. SDF and CSV files are supported, and source fields are automatically matched to Collection properties when their names align. During mapping, fields can be reassigned, fixed values or default units can be supplied, and unmapped columns can be created as new properties.

Image 5 from Signals ChemDraw What's New 26.8_October_2026.docx

When the import is complete, a notification is provided and an import report is available from the Import Reports page, accessible from the user menu.

Image 6 from Signals ChemDraw What's New 26.8_October_2026.docx

Collections can also be moved out of ChemDraw+ for sharing or use in other applications by exporting the entire Collection or selected entries as an SDfile. All associated properties are included, and export progress is displayed until the file is ready.

Image 7 from Signals ChemDraw What's New 26.8_October_2026.docx

Within ChemDraw+, Collections can be shared with individuals or groups to support collaboration. Frequently used Collections can be added to Favorites for quick access, while all available Collections remain accessible from the Collections folder. Collections can also be moved between Notebooks or moved to and restored from Trash. Available actions depend on role-based permissions, and Collections in Trash remain available in read-only mode.

Signals Configuration

Configure Collections system object

Image 8 from Signals ChemDraw What's New 26.8_October_2026.docx

A new Collections system object in Signals Configuration brings Collection settings together in one place. Here, administrators can grant the Share, Move and Trash privileges per user role, with the same controls mirrored on the User Roles page. Where a role lacks a privilege, the corresponding button or menu option is hidden in the application.

Image 9 from Signals ChemDraw What's New 26.8_October_2026.docx

The Properties page provides a complete view of the automatically calculated chemical properties available for Collections. Administrators can also define custom properties to support additional scientific data, using text, number, number with unit, integer, date, date and time, list, multi-select list, attribute list, hyperlink, or internal reference data types. Once added, custom properties are available for use across Collections.

Image 10 from Signals ChemDraw What's New 26.8_October_2026.docx

Collections include a Default template that makes it easy to create a new Collection with a predefined set of properties. Administrators can create additional templates for different types of Collections, such as small molecules or biopolymers, and configure the properties included in each template. Templates provide a convenient starting point without limiting available data: all calculated system properties can be added to a Collection, regardless of the template used.

What’s New

We are delighted to release our new version of Katalyst D2D®, Version 26.

Highlighted Features

  • Data clustering to improve interpretation of chromatographic results.
  • Improvements to the Signals Notebook integration.
  • Visualization and interpretation of chromatographic results through peak coloration.
  • End-to-end data capture and sample tracking across high throughput purification workflows.

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

Further Details

Katalyst D2D 26.1

Released April 2026

Version 26.1 introduces data clustering to improve interpretation of chromatographic results, and improvements to the Signals Notebook integration.

Experiment Design

  • Create mixtures with more than two solvents.
  • Assign total volume option for mixtures.
  • Perform aspirate and dispense actions within the same container.

Data Analysis

  • Group unknown chromatographic peaks across wells.
  • Create data clustering plots.
  • Import preprocessed chromatographic data sets (i.e. peak integrations from third-party software).
  • Calculate initial rates of decay in kinetic plots.

Signals Integration

  • Export multiple custom calculations/functions to Signals Notebook experiments, e.g., yield, % ee, conversion.
  • Map material classes upon import of experiments from Signals Notebook into Katalyst D2D.

Ease of Use

  • Notifications (pop-up and email) for successful and failed experiment finalization.
  • Link related experiments.

Katalyst D2D 26.2

Released July 2026

Version 26.2 introduces new features for visualization and interpretation of chromatographic results through peak coloration, and further enhancements to the Signals Notebook integration.

Data Analysis

  • Option to apply chromatographic peak colors for material classes.
  • Direct batch import of analytical data files to experiments.
  • Expansion of Tables widget to include Analysis type, Instrument parameters, and Analytical Data Table values.
  • SuntheticsML integration—push Bayesian (EDBO+) optimization results into Sunthetics for data visualization.

Signals Integration

  • Export custom tables to Signals experiments.
  • Expanded import of configurable Signals Property fields (meta data) .
  • ‘Reactant Role’ in the Signals Subexperiment Layout is populated with Katalyst material class values.

Katalyst D2D 26.3

Released October 2026

Version 26.3 introduces end-to-end data capture and sample tracking across high throughput purification workflows and other improvements.

Introducing support for high throughput (HT) purification workflows

  • Submit samples to a searchable submission dashboard. The software tracks the progress and status of each sample.
  • Automatic mapping of the best prep method for each sample, or sets of samples, based on results of crude QC runs.
    • Auto-processing and visualization of chromatograms.
    • Select method scoring parameters to define the “best method”.
    • Choose to override automatically selected “best method”.
  • Track sample and vial mapping between prep vial locations and fraction vial locations.
  • Set criteria for fraction pooling. The software auto-recommends the appropriate vials for fraction pooling (visualize color-coded fraction pooling in plate format).
  • Email notifications are sent once sample purification is complete.

Experiment Design

  • Option to set recursive or non-recursive search of material databases.
  • Define well barcodes (previously barcodes could only be defined for plates).
  • Import mixtures via SD files.

Data Analysis

  • Improved 2D NMR data visualization (expansion of 2D NMR data types and more).

What's New

We are delighted to release our new version of Signals, 26.8.

The following improvements are available for users, administrators and developers on the Signals platform. Certain features may only be available with appropriate licensing and/or with enablement by an administrator.

  • Fundamentals
    - SMILES management in Solvate list
    - Product selection on Bulk Sample creation in Parallel Experiments
    - Mapping of HELM string in External Enumerator
    - Audit trail displays highlighted granular changes for structured tables such as hierarchical tables, variations tables, materials tables, etc is available to all systems
    - Audit trail displays highlighted granular changes for worksheets is available to all systems
    - Audit trail displays highlighted granular changes for ChemDraw Stoich Grid
    - Manage assay variant lifecycles and compliance* (beta)
  • Data Workflows & Analytics*
    - Create and assign custom parameter sets
    - Fit linear concentration data using new system Agonist and Antagonist dose-response models
  • SAR & Decisioning*
    - Use Insights to query, generate, and analyze Measurement and SAR Tables directly in Signals is available to all systems
    - Explore key results faster in Insights with a cleaner default SAR table and dynamic chemical structure filtering directly
    - ChemCharts: New antibody engineering and molecule alignment data functions, plus updates to visualization settings including visual cloning and per-column tooltips
  • Synergy†
    - Designs now support LogP, predicted pKa, Labute ASA, and other calculated properties
    - Designs import now supports CSV with HELM notation
    - Work Order properties can inherit from Collaboration properties
    - CRO users can print Synergy Experiments to PDF
    - New Sponsor notification when a CRO user puts a Work Order On Hold
    - Audit trail displays highlighted granular changes for Design tables
  • Tables
    - Default values for Headers and Properties in Admin Defined Tables and Variation Tables
    - Default values for Headers and Properties in Hierarchical Tables*
    - Display Mean in Box Plots*
    - Define Reference Lines on charts*
    - Define charts on Variation Tables*
  • Plates
    - Hide column in table when Annotation layer is hidden
  • Inventory
    - Record consumed quantities directly from a container while automatically tracking the remaining balance and vice versa
    - Support for Material Orders custom field types
    - Faster Quick Add Workflow in ChemDraw Document
    - Prevent the creation of grid sub-locations within designated home location cells
    - New Container Label Templates - 50 x 30 mm (QR Code) and 50 x 30 mm (4 slots)
    - Design and customize Inventory label templates layouts (beta)
    - Reconciliation and Rectification details added to Container Search Table
  • InventoryGo ‡
    - Support for Barcode and QR Code Scanning via Camera scanning
  • Materials
    - Bulk update materials tables
    - HELM String calculated property
  • ELN Archive
    - Combined ELN Archive and Signals Search (beta)
  • Administration
    - Configure Data Factory maps to support user-defined fixed values*
  • Integrations & APIs
    - Create Material Order via API
    - FASTA support for writing to Chemical Drawings via API
    - Fetch Material Reports via API
  • Xynthetica*
    - Xynthetica Administrative UI (beta)
  • Formulations*
    - Formulations Development (beta)

* Requires Signals One license

† Requires Signals Synergy license

‡ Requires InventoryGo license

We also fixed several small bugs in this release. Details of the enhancements are described below.

The following OnDemand videos for Signals Notebook Administrators are now available:

  • Data Exchange Mapping Settings for Publication to Data Factory
  • Synergy Experiment Mapping Settings for Publication to Data Factory

Data Factory now enforces a limit of 100 endpoints per measurement type

Data Factory administrators should be aware that all primary APIs will be deprecated in a future release.

Data Factory administrators should be aware that ‘username’ has been removed from the primary API GET /datafactory/search-service/my-saved-searches

Data Factory Administrators should complete migration of legacy data factory projects before 27.4; after this the migration deadline, legacy projects will become read-only and no longer support data publication.

Data Factory administrators should also note that the Advanced Security policies in Inventa apply an “AND” logic across all user groups, restricting access if any groups lack permissions. This behavior differs from the standard Signals security model and will be fixed to align with the standard in a future release.

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

This content is anticipated for release on our Production E3 environments, and for Private Cloud customers on our deferred release schedule, in March 2027.

Further Details

The following improvements are available for users, administrators and developers on the Signals platform. Certain features may only be available with appropriate licensing and/or with enablement by an administrator.

Fundamentals

Image 1 from What's New 26.8.docx

In preparation for expanding the Salt Stripping functionality of Normalized Compounds to Solvates, the Solvates list in the SN Config has been updated to allow for SMILES management as well.

To manage Solvate SMILES, the user can navigate to the Solvate list in the System Settings

Image 2 from What's New 26.8.docx

The SMILES for the System provided Solvate list can be added by “Exporting System Solvates To .csv” and Bulk updating Solvates. Individual Solvate SMILES can be entered directly in the Text SMILES column.

In Parallel Experiments, users will now have the option to select which Product to use on Bulk Sample creation. When the user goes to Bulk create samples, there will now be an option to select which product to use in sample creation, ie. P1 or P2. Utilizing the “All Products” selection will preserve existing behavior.

Image 3 from What's New 26.8.docx

The HELM string is now an available option for mapping the Chemical Structure in the External Enumerator.

Image 4 from What's New 26.8.docx

Users can view visual granular change comparisons for ChemDraw Stoichiometry Grids in the audit trial. When enabling the “View granular changes” toggle, field and value updates are clearly highlighted: green indicates newly added data, a green dashboard boarder denotes modified data, and gray represents removed entries. This visual comparison also applies to the Reactants Summary table as well as table visibility changes (showing or hiding stoichiometry tables). Note: visual diffs for Chemical drawings (molecular diagrams) are not supported by this tool.

Data Workflows & Analytics

Image 5 from What's New 26.8.docx

In the Curve Fitting step of the In Vitro Analysis, following an analysis run, it is now possible for Signals One users to select some of the curves and apply a new set of fit parameters to these curves specifically to improve their curve fitting.

Image 6 from What's New 26.8.docx

A new pull down menu in the bulk actions bar is now available to set the fit parameters:

Image 7 from What's New 26.8.docx

Each new set of curve fitting parameters, identified by a name, can then be applied to the selected curves for recalculating the curve fits.

Image 8 from What's New 26.8.docx

The name of the parameter set remains associated with the curves that were recalculated with it.

Image 9 from What's New 26.8.docx

Finally, the parameter sets in the analysis, which can be part of the In Vitro Analysis template, can be managed by clicking on the cog wheel in the upper right corner of the Curve Fitting element. The number of curve fits using each of the parameter sets is visible:

Image 10 from What's New 26.8.docx

When deleting a set of parameters used to recalculate some of the curves, the default parameters used for the initial global run are automatically reapplied.

Image 11 from What's New 26.8.docx

Moreover, in addition to the 3, 4 and 5 Parameters logistic curve fitting definitions, eight new system definitions are now available in the Analytics smart folder of Signals One configuration.

These new definitions, which can be enabled or disabled, allow using linear concentrations of agonists or antagonists with either raw or normalized signal.

SAR & Decisioning

Image 12 from What's New 26.8.docx

Use Insights to query, generate, and analyze Measurement and SAR Tables directly in Signals is available to all systems

Image 13 from What's New 26.8.docx
Image 14 from What's New 26.8.docx

Insights now supports advanced chemical filtering within SAR and Measurement Tables, including substructure, similarity, exact, full-structure, and tautomer matching. Multiple filters can be combined to refine results, while chemical fragment highlighting provides additional context during analysis. A cleaner default SAR table layout helps users focus on key endpoints, with additional data available through table configuration options.

Image 15 from What's New 26.8.docx
Image 16 from What's New 26.8.docx
Image 17 from What's New 26.8.docx
Image 18 from What's New 26.8.docx
Image 19 from What's New 26.8.docx
Image 20 from What's New 26.8.docx
Image 21 from What's New 26.8.docx
Image 22 from What's New 26.8.docx

ChemCharts introduces new data functions for antibody engineering and molecular alignment, along with visualization enhancements such as visual cloning and per-column form tooltips.

ChemCharts now supports assigning different form-based tooltips to individual columns, providing greater control over the contextual information displayed throughout a visualization. New visual cloning capabilities also make it easier to duplicate and adapt existing visualizations.​

The Antibody Numbering data function now supports ANARCII and can return prediction scores and confidence values for heavy and light chains.​

The Gaussian Molecular Shape Alignment data function aligns small molecules to a query structure using Gaussian 3D shape-based alignment. Results are returned in Query Conformers and Aligned Structures tables and can be explored using the Molecule Viewer.​

The Antibody Germline Prediction and Antibody Humanization data functions support complementary antibody engineering workflows. Germline Prediction identifies the most likely germline gene families for heavy and light chains and aligns sequences to identify mutations relative to the highest-probability germline sequence. Humanization then suggests sequence changes intended to improve predicted human-likeness while maintaining antibody chain pairing characteristics. When used with the Biomolecule Viewer, users can compare the original and predicted humanized structures.

Synergy

Image 23 from What's New 26.8.docx

Release 26.8 brings several updates to Synergy Designs. First, calculated properties, including a variety of physicochemical properties (e.g., Log P, predicted pKa), drug-likeness and ADME predictors (e.g, Labute ASA, Lipinski H-bond acceptors), structure and topology, ring system, atomic composition, and stereochemistry calculations, are now available for Synergy Designs. Administrators can selectively configure which properties to include in each library’s Designs Definition and Design Tables in Synergy Configuration by adding a new field and selecting Calculated Property.

Image 24 from What's New 26.8.docx

When new Designs are created, properties are automatically calculated and represented on the Design.

Image 25 from What's New 26.8.docx
Image 26 from What's New 26.8.docx
Image 27 from What's New 26.8.docx

In this release, bulk Import Designs to Designs Table now supports CSV files with HELM notation. Note that Designs already support HELM notation; this is an expansion of the import file CSV file support.

Image 28 from What's New 26.8.docx

Currently, Synergy Experiment properties can be configured to inherit property values from the parent Collaboration or associated Work Order. In 26.8, we extended this feature to Work Orders. Work Order Template attribute list fields can be configured to inherit a corresponding property value from the parent Collaboration. If a field is set to inherit from the Collaboration, the Work Order field will automatically populate with the corresponding value from the parent Collaboration at creation. As a result, the Sponsor user does not have to repeatedly populate the same property, such as Project Code or Disease Target, even when this property is Hidden from CRO.

Image 29 from What's New 26.8.docx

Similar to Sponsor users, CRO users can now Print to PDF their Synergy Experiments. As always, Hidden from CRO metadata is excluded from the print PDF functionality for CROs.

Image 30 from What's New 26.8.docx

Sponsor users can receive an in-app or email notification when a CRO user puts a Work Order On Hold.

Image 31 from What's New 26.8.docx

Sponsor Administrators can view visual granular change comparisons for fields in Synergy Design tables in the audit trial. When enabling the “View granular changes” toggle, field updates are clearly highlighted: green indicates newly added data, a green dashboard boarder denotes modified data, and gray represents removed entries. Use cases addressed include adding a new field to a Design, updating or clearing field values, renaming a field header, removing a field or reordering columns. Note: Design Structure previews are not supported by this tool.

Tables

Image 32 from What's New 26.8.docx

Configuration administrators can now define default values for Headers and Properties in Admin Defined Tables, Variation Tables and Hierarchical Tables. Default values can be set for all appropriate property types.

Image 33 from What's New 26.8.docx

The Mean can now be displayed in Box Plots. The Configuration Administrator, or optionally the end user, can set if the Mean is displayed or not, and define the color, line style and line thickness.

Image 34 from What's New 26.8.docx

Reference Lines can be displayed on numerical axes of charts. Lines can be set to be either a fixed value or at a calculated aggregate of a numerical column. The configuration administrator, or optionally end user, can define the line color, style and thickness, and the label display, for the reference lines.

Image 35 from What's New 26.8.docx

Graphing has also been extended to Variation Tables. All included chart types, namely Scatter Plots, Bar Charts, Bar Charts and Box Plots can be configured on Variation Table Templates. The Variant Name can be used as a categorical property, such as to Trellis By.

Plates

Image 36 from What's New 26.8.docx

When users Hide an Annotation layer in the plate, the corresponding column in the Plate table is also hidden. This will not alter the data stored on the plate.

Inventory

Image 37 from What's New 26.8.docx

Create and customise inventory label templates by defining label sizes, selecting displayed fields, positioning content, and configuring formatting options such as fonts, barcodes, and QR codes to meet site-specific labelling requirements.

Image 38 from What's New 26.8.docx

Enter the amount consumed directly during inventory updates. The system automatically deducts the consumed quantity and displays the remaining balance, simplifying inventory consumption tracking.

Image 39 from What's New 26.8.docx
Image 40 from What's New 26.8.docx

Configure custom fields for material orders and capture additional information tailored to your organization’s procurement and inventory workflows.

Image 41 from What's New 26.8.docx

When searching for items in Quick Add (via barcode scan, container ID, material name, or sample search), the system now automatically selects the item and bypasses the search
modal whenever a single match is found, eliminating unnecessary dialogs and clicks.

Image 42 from What's New 26.8.docx

To maintain location hierarchy integrity and prevent configuration conflicts, the system now validates grid cells before sub-location creation. Users are prevented from converting any grid cell that is already assigned as a container’s Home Location into a Grid-type sub-location.

Image 43 from What's New 26.8.docx
Image 44 from What's New 26.8.docx

New Container Label Templates - 50 x 30 mm(QR Code) and 50 x 30 mm(4 slots)

Image 45 from What's New 26.8.docx

Container search results now display reconciliation and rectification details, providing greater visibility into inventory status and recent inventory adjustments.

InventoryGo

Image 46 from What's New 26.8.docx

Scan barcodes and QR codes directly using your device’s camera, enabling faster identification and management of inventory items without dedicated scanning hardware.

Materials

Image 47 from What's New 26.8.docx

Materials tables within an experiment can now be updated in bulk to reflect the latest material changes. Users can now select multiple rows that contain stale data and update them in one action.

Image 48 from What's New 26.8.docx

A new calculated property in Compounds and Normalized Compounds libraries and the pre-configured Reagents (SNB) library is available to generate a HELM string of the structure drawn in the ChemDraw canvas.

Administration

Image 49 from What's New 26.8.docx
Image 50 from What's New 26.8.docx
Image 51 from What's New 26.8.docx
Image 52 from What's New 26.8.docx

Data Factory file maps now allow user to supply a constant value when publishing data via the Inventa Dashboard or Publish Results to Data Factory app. Administrators can enable the “Fixed” value from an Entity or Measurement Type map from the Data Factory configuration. When users select this map during publication either via the Inventa Dashboard or the Publish Results to Data Factory app they are prompted to enter a value. This value will appear on every row for that column in the publication.

Integrations & APIs

Image 53 from What's New 26.8.docx

We have added a new API to create material orders (POST /inventory/materialOrders). The request sets the order fields, for example Requestor, Supplier Name, Supplier Catalog Number, Destination Location and Status. The Destination Location can be a grid location. The Chemical Structure field accepts CDXML, SMILES, InChI, MOL V2000, MOL V3000 and HELM.

Image 54 from What's New 26.8.docx

We have enhanced the Chemical Drawing APIs to support FASTA sequences. The API to append a structure to a reaction (POST /chemicaldrawings/{eid}/reaction/{position}) now accepts the data types “fasta-dna”, “fasta-rna” and “fasta-peptide”.

Image 55 from What's New 26.8.docx

We have added new APIs to fetch the reports of all material bulk import, bulk export and bulk update jobs (GET /materials/bulkImport/jobs, /materials/bulkExport/jobs and /materials/bulkUpdate/jobs). Each API returns a paged list of jobs with their status and results.

Beta Features

The following capabilities are in beta and are available for users, administrators and developers on the Signals platform upon request. Please contact your account representative or our support team if you would like access to the following features.

Fundamentals

Image 56 from What's New 26.8.docx
Image 57 from What's New 26.8.docx
Image 58 from What's New 26.8.docx
Image 59 from What's New 26.8.docx
Image 60 from What's New 26.8.docx
Image 62 from What's New 26.8.docx

Assays and their Variants now support Archiving. If a Variant is no longer needed for production use, it can be marked as Archived, which will prevent further editing of the Variant, unless it is restored

Configuration admins may need to update a Variant template after its in use, for example to add an additional data capture field. When a administrator modifies a template, users will see an outdated message on the Variants Summary table. When they select update, the table will be updated with the latest definition, and the existing Variants checked for compliance with that new definition. Users can individually edit Variants to meet the up dated definition requirements. Assay state and compliance are both searchable fields and clear labels on the Variant. The parent Assay’s state and compliance is automatically updated based on it’s Variants.

ELN Archive

Image 63 from What's New 26.8.docx

Users can now conduct a simultaneous search across Signals Notebook and ELN Archive content. This search is available via a new combined Source and allows users to query both sets of content by text and chemical structure. Each set of content can be further refined using facets specific to that set of content.

Xynthetica

Image 64 from What's New 26.8.docx
Image 65 from What's New 26.8.docx

Xynthetica now supports a native admin UI.

The Tenant Models pane gives the administrator a navigable UI to see details around how their users are leveraging Xynthetica models.

Image 66 from What's New 26.8.docx

The Model Marketplace is used to gain access to models, and their model card information can be viewed by simply clicking into the relevant model of interest.

Image 67 from What's New 26.8.docx

Data Contribution allows users to commit training data to federated models. User selects values of interest and parameter, then submits relevant metadata to improve.

Image 68 from What's New 26.8.docx

Monitor credit spend in the Credits panel. The Xynthetica-Tunelab bundle includes 2M starter credits.

Formulations

Image 69 from What's New 26.8.docx

Formulation Development will need some administration set up before it can be used. Activation is in the System Objects à Formulation Experiment:

Image 70 from What's New 26.8.docx

There is only 1 Default System Template currently supported. User Roles has a heading for managing permission to User Roles. Formulation Experiments permissions are for Signals Notebook users:

Image 71 from What's New 26.8.docx

Recipe Designer App is for users that will be creating Parameters, Steps, Recipes and Formulation Experiment Designs:

Image 72 from What's New 26.8.docx

There is a new System Group called Recipe Builders. All Steps, Recipes and Formulations Experiment Designs are automatically shared with the Recipe Builder group by default. The Equipment Table for Formulations can be adjusted in the Material Library:

Image 73 from What's New 26.8.docx

A new Material Library called Formula (SNB) has been created and will need to be set up with an ID Sequence, Uniqueness Rule and Record Definition for both the Material and the Batch/Lot, as well as activated:

Image 74 from What's New 26.8.docx

Before any parameters can be created, the System Administrator must set up the Controlled Fields in the System Settings in SN Config:

Image 75 from What's New 26.8.docx

Once the above items have been configured, users with the role with Recipe Builder/permissions to the Recipe Designer App can log into the new app from the home page or via the top right navigation:

Image 76 from What's New 26.8.docx

In the Recipe Designer App, users can create Parameters, Steps, Recipes and Formulation Experiment Designs. Parameters are created from the Controlled Fields that the System Administrator has created:

Image 77 from What's New 26.8.docx

Parameters Table can have additional columns and calculations added to them:

Image 78 from What's New 26.8.docx

Use the Create New menu to create Steps, Recipes and Formulation Experiment Designs:

Image 79 from What's New 26.8.docx

Steps require the Instructions box, but Ingredients, Equipment and Parameters are optional. Steps can be deleted if not used, otherwise they can be retired.

Image 80 from What's New 26.8.docx

Recipes require space for Steps, but Ingredients, Equipment and Parameters are optional. Recipes can be deleted if not used, otherwise they can be retired.

Image 81 from What's New 26.8.docx

Parameters, Steps and Recipes can be used to create a Formulation Experiment Design. The Formulation Experiment Design acts like a template that Formulators can use to create new Formulation Experiments from.

Image 82 from What's New 26.8.docx

Select the Material Libraries that will be needed:

Image 83 from What's New 26.8.docx

Select Properties and Ingredients can be adjusted in the Ingredients Table in the Formulation Experiment Design or in the Formulation Experiment. Equipment types can be filled in. Recipes, Steps and Parameters can be added and adjusted on the Formulation Experiment Design. Once ready, share the Formulation Experiment Design with the correct Users or User Groups to be used in Signals Notebook. Formulation Experiment Designs can be deleted if not used or retired in the top right corner.

Image 84 from What's New 26.8.docx

Users in the role with permission to create Formulation Experiments will see the option under the Add New menu:

Image 85 from What's New 26.8.docx

Select a Formulation Experiment Design to start a new Formulation Experiment:

Image 86 from What's New 26.8.docx

Make updates to the Ingredients, Equipment, Recipes, Steps and Parameters as needed:

Image 87 from What's New 26.8.docx

When done making changes, click the Continue to Lots button. Select an asset from the Formula Library and enter the number of batches/lots to create for this experiment:

Image 88 from What's New 26.8.docx

Enter required data on the Lot Definitions before moving to the Lot Composition:

Image 89 from What's New 26.8.docx

Fill in the Lot Composition to Register the lots directly from the Formulation Experiment:

Image 90 from What's New 26.8.docx

Once the lots have been registered, users will see the Lot IDs have been replaced with real Material IDs and the Lot Recipes will be repeated on a per lot basis:

Image 91 from What's New 26.8.docx

Users can make changes on a per lot basis to the Recipe, Steps or Parameters. Once changes are completed, users can click the Start Execution button to capture the experiment data as they run the experiment:


What’s New

We're delighted to introduce ChemDraw Desktop 26.1, which delivers enhancements that improve security, administrative flexibility, and chemistry workflows. This release adds support for modern authentication standards, expanded deployment controls for administrators, and improvements to structure naming and editing capabilities. We have also addressed several bugs and usability issues to provide a more seamless experience.

ChemDraw Desktop

  • Authentication & Administration Improvements 
  • Chemistry & Drawing Improvements

ChemDraw Desktop

Authentication & Administration Improvements

Administrators can now disable automatic updates for ChemDraw Desktop deployments. This provides greater control over software rollout and validation processes in regulated or managed IT environments. Configuration options are available for both Windows and macOS deployments.

ChemDraw for Excel now prompts users to sign in only when ChemDraw functionality is accessed. Previously, users were prompted to authenticate whenever Excel was launched with the add-in installed.

Signals ChemDraw now supports Proof Key for Code Exchange (PKCE) authentication when signing into Signals. This enhancement improves compatibility with modern authentication standards and organizational security requirements.

Chemistry & Drawing Improvements

Image 1 from 26.1 ChemDraw Desktop September 2026.docx

ChemDraw naming capabilities have been expanded to support mixtures containing non-integral component ratios. This improves handling of chemically relevant mixtures and generates more accurate nomenclature for these structures.

Image 2 from 26.1 ChemDraw Desktop September 2026.docx

When a structure contains an attached data label, selecting the label now automatically highlights the atoms associated with that label. This makes it easier to identify the portion of the structure represented by the selected data.

Image 3 from 26.1 ChemDraw Desktop September 2026.docx

The Edit > Paste Special menu has been updated to provide separate options for CDXML Text and MDL Text. Previously, both formats were combined into a single menu item. The existing keyboard shortcut remains associated with CDXML Text, while MDL Text is available as a separate option.

What’s New

We are delighted to release our new version of AutoChrom®, Version 2026.

Highlighted Features

  • Accelerate method development with end-to-end automation.
  • Create composite chromatograms.
  • Improved searchability of method parameters in database.

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

Further Details

Version 2026 adds new features including end-to-end automation of method development. There are also improvements to reporting, and more.

Data Analysis & Processing

Accelerate Method Development with End-to-End Automation

New end-to-end automation capabilities streamline method development workflows. You can now automate the entire method development lifecycle from screening through optimization, reducing hands-on time, minimizing human error, and enabling unattended execution of routine workflows, so methods can run overnight or in the background.

  • The new Auto-Proceed feature automates almost every step of a standard method development workflow (excluding data processing), saving time and improving workflow consistency.

Create Composite Chromatograms

You can now create a single composite chromatogram by combining multiple experimental chromatograms acquired using the same chromatographic method, to provide a clearer representation of the expected separation when method suitability criteria are met.

  • Composite chromatograms are automatically labeled with an asterisk (*) after the original chromatogram name, helping you to quickly identify combined data in your project.
  • Two experimental chromatograms can be merged when: 

    • All optimization factor values are defined and identical between chromatograms

    • Chromatograms use the same detector parameters

Easier Interpretation of Method Optimization Results

  • You can now view the calculated Method Operable Design Region (MODR) as both a graphical rectangle and numeric text in the status bar of the Resolution Map window, making it easier to interpret optimization results and identify suitable operating conditions.

Simplified Configuration of Autonomous Processing

  • You can now edit the configuration settings for Autonomous Processing in a dedicated dialog box, making it easier to configure, save, and reuse processing parameters.

Component Spectrum Flexibility

  • You can now create component spectra based on the most abundant adduct ion ([M+H]+, [M+NH4]+, [M+K]+, etc.) This is particularly useful when the [M+H]+ ion is weak or exhibits a very low intensity.

Better Handling of Peptide Structures

  • Peptides can now be displayed in a simplified form in the Table of Components, making it easier to distinguish and interpret individual structures.

Import Components without Retention Time Assignments

  • You can now use existing datafiles to generate target lists (.sdf) for more streamlined batch processing. Components can be imported with or without existing retention times, reducing erroneous assignments and enabling reuse of component files across targeted analysis and other workflows.

Display Combined Retention Time

  • You can now display the combined retention time (tR) instead of scan numbers for clearer interpretation of chromatographic data.

Databasing

Improved Searchability of Method Parameters in Database

Enhancements to method parameter management in the database minimizes time-consuming manual searches and removes the need to recreate project files. You can now expect greater ease in searching and maintaining LC Simulator projects with the ability to:

  • Add LC Simulator files (.lc7) to the database, enabling rapid retrieval and comparison of method parameters across projects
  • Maintain and update stored method information without recreating project files by editing/updating stored .lc7 files, including chemical structures, selection mode, and prediction mode, preserving your existing work and streamlining ongoing method management.

More Convenient Review of LC Simulator Project Records

Managing and reviewing LC Simulator projects is now faster and more intuitive. You now have a ready-to-use database template and improved navigation that reduces the time spent searching for and switching between related projects. You can now edit and update LC Simulator (.lc7) files in Spectrus databases.

  • A new example Spectrus DB database record containing the LC Simulator Project screen form provides a ready-to-use template for creating local or remote LC Simulator project databases, eliminating the need to build project structures from scratch.
  • Improved navigation allows you to move between multiple LC Simulator projects stored on the same parent record more quickly and easily, reducing review time and keeping your workflow moving.
  • You can now create a Spectrus DB screen form for convenient review of LC Simulator Project records.
Image 1 from WN AutoChrom v2026.docx

Handle LC Simulator files in database view.

Ease of Use

  • Choose to hide the “Custom Screen Form” toolbar for greater screen real-estate.
  • You now have a new option to visualize the stereochemical configuration of select stereocenters in database records. Previously you could either display or hide all stereocenters.

Reporting

Greater Flexibility and Consistency Across Reporting

Reporting templates have been enhanced to provide greater flexibility and consistency across products.

  • The reporting template now supports gradient substitution, MODR substitution for the current variable gradient parameter, and custom defined gradient parameters.

These enhancements simplify report creation and enable more comprehensive presentation of method development results.

Select Components for Reporting

  • You can now choose which components from the Table of Components are included in reports when using the Component/Peak Layout Organizer.

Simplified Peptide Reporting

  • You can now report peptides in a simplified form for clearer presentation in reports.

Ease of Use

  • You can now more easily locate and configure frequently used settings with the simplified Component Interpretation Options dialog box.

Data Import & Export

Improved MS & Chrom Data Import

  • Improved import filters for Thermo UVPD MSn data.

Include Structure Information in Data Exported in JSON Format

  • You can now include structure information in records/databases exported in JSON format via .mol files.

Processing NMR Data

Data Analysis & Processing

Internal Standard qNMR Concentration Calculation Now Included Out of the Box

  • Internal standard qNMR calculations are now available in the interface, similar to the external standard workflow (previously available as a script provided upon request).

Conveniently Calculate Similarity Score Between Two 1D Spectra

  • You can now calculate the Hit Quality Index (HQI) between two 1D spectra of the same nucleus without the need for the reference spectrum to be in a database. This can provide a quick quantification of the match between the current sample spectrum and that of a standard.

Better Peak Handling for 19F Spectra with Strong Couplings

  • You can now automatically pick and assign peaks in 19F spectra of structures containing CHF2 groups more accurately. When the proposed structure contains these groups, the software checks the spectrum for peaks associated with a typical AB spin system for F atoms (two strongly coupled doublets with an evident ‘roof’ effect).

Expanded 1H-31P Coupling Ranges in Auto Assignment

  • You can now more accurately assign and verify structures whose spectra contain large 1H-31P coupling constants with increased upper limits for JHP. The new expanded ranges are: 

    • 3–20 Hz for 2JHP

    • 0–20 Hz for 3JHP

    • 0–6 Hz for 4JHP

Define Parameters Once for All Replicates in External Standard qNMR

  • You can now define parameters including pulse angle, scans, and receiver gain once and have them applied to all selected spectra in external standard qNMR workflows with replicates when they cannot be automatically extracted from the raw data files.

Reporting

Set the Relative Height of “Median” Peak in Report

  • You can now better control the “Fit” option for dynamic Y-scaling of the 1D spectra in the reporting templates with the new Ratio parameter that allows you to specify the relative height of the “median” peak in the report.
Image 2 from WN AutoChrom v2026.docx

Use the new ratio parameter for dynamic y-scaling of 1D spectra. 
Left spectrum has a fit = 90%, right = 10%

What’s New

We are delighted to release our new version of Method Selection Suite ™, Version 2026.

Highlighted Features

  • Create composite chromatograms.
  • Improved searchability of method parameters in database.

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

Further Details

Version 2026 adds new features including the creation of composite chromatogram. There are also improvements to searchability parameters, and more.

Data Analysis & Processing

Create Composite Chromatograms

You can now create a single composite chromatogram by combining multiple experimental chromatograms acquired using the same chromatographic method, to provide a clearer representation of the expected separation when method suitability criteria are met.

  • Composite chromatograms are automatically labeled with an asterisk (*) after the original chromatogram name, helping you to quickly identify combined data in your project.
  • Two experimental chromatograms can be merged when: 

    • All optimization factor values are defined and identical between chromatograms

    • Chromatograms use the same detector parameters

Component Spectrum Flexibility

  • You can now create component spectra based on the most abundant adduct ion ([M+H]+, [M+NH4]+, [M+K]+, etc.) This is particularly useful when the [M+H]+ ion is weak or exhibits a very low intensity.

Better Handling of Peptide Structures

  • Peptides can now be displayed in a simplified form in the Table of Components, making it easier to distinguish and interpret individual structures.

Import Components without Retention Time Assignments

  • You can now use existing datafiles to generate target lists (.sdf) for more streamlined batch processing. Components can be imported with or without existing retention times, reducing erroneous assignments and enabling reuse of component files across targeted analysis and other workflows.

Display Combined Retention Time

  • You can now display the combined retention time (tR) instead of scan numbers for clearer interpretation of chromatographic data.

Databasing

Improved Searchability of Method Parameters in Database

Enhancements to method parameter management in the database minimizes time-consuming manual searches and removes the need to recreate project files. You can now expect greater ease in searching and maintaining LC Simulator projects with the ability to:

  • Add LC Simulator files (.lc7) to the database, enabling rapid retrieval and comparison of method parameters across projects
  • Maintain and update stored method information without recreating project files by editing/updating stored .lc7 files, including chemical structures, selection mode, and prediction mode, preserving your existing work and streamlining ongoing method management.

More Convenient Review of LC Simulator Project Records

Managing and reviewing LC Simulator projects is now faster and more intuitive. You now have a ready-to-use database template and improved navigation that reduces the time spent searching for and switching between related projects. You can now edit and update LC Simulator (.lc7) files in Spectrus databases.

  • A new example Spectrus DB database record containing the LC Simulator Project screen form provides a ready-to-use template for creating local or remote LC Simulator project databases, eliminating the need to build project structures from scratch.
  • Improved navigation allows you to move between multiple LC Simulator projects stored on the same parent record more quickly and easily, reducing review time and keeping your workflow moving.
  • You can now create a Spectrus DB screen form for convenient review of LC Simulator Project records.
Image 1 from WN Method Selection Suite v2026.docx

Handle LC Simulator files in database view.

Ease of Use

  • Choose to hide the “Custom Screen Form” toolbar for greater screen real-estate.
  • You now have a new option to visualize the stereochemical configuration of select stereocenters in database records. Previously you could either display or hide all stereocenters.

Reporting

Select Components for Reporting

  • You can now choose which components from the Table of Components are included in reports when using the Component/Peak Layout Organizer.

Simplified Peptide Reporting

  • You can now report peptides in a simplified form for clearer presentation in reports.

Data Import & Export

Improved MS & Chrom Data Import

  • Improved import filters for Thermo UVPD MSn data.

Include Structure Information in Data Exported in JSON Format

  • You can now include structure information in records/databases exported in JSON format via .mol files.

Processing NMR Data

Data Analysis & Processing

Internal Standard qNMR Concentration Calculation Now Included Out of the Box

  • Internal standard qNMR calculations are now available in the interface, similar to the external standard workflow (previously available as a script provided upon request).

Conveniently Calculate Similarity Score Between Two 1D Spectra

  • You can now calculate the Hit Quality Index (HQI) between two 1D spectra of the same nucleus without the need for the reference spectrum to be in a database. This can provide a quick quantification of the match between the current sample spectrum and that of a standard.

Better Peak Handling for 19F Spectra with Strong Couplings

  • You can now automatically pick and assign peaks in 19F spectra of structures containing CHF2 groups more accurately. When the proposed structure contains these groups, the software checks the spectrum for peaks associated with a typical AB spin system for F atoms (two strongly coupled doublets with an evident ‘roof’ effect).

Expanded 1H-31P Coupling Ranges in Auto Assignment

  • You can now more accurately assign and verify structures whose spectra contain large 1H-31P coupling constants with increased upper limits for JHP. The new expanded ranges are: 

    • 3–20 Hz for 2JHP

    • 0–20 Hz for 3JHP

    • 0–6 Hz for 4JHP

Define Parameters Once for All Replicates in External Standard qNMR

  • You can now define parameters including pulse angle, scans, and receiver gain once and have them applied to all selected spectra in external standard qNMR workflows with replicates when they cannot be automatically extracted from the raw data files.

Reporting

Set the Relative Height of “Median” Peak in Report

  • You can now better control the “Fit” option for dynamic Y-scaling of the 1D spectra in the reporting templates with the new Ratio parameter that allows you to specify the relative height of the “median” peak in the report.
Image 2 from WN Method Selection Suite v2026.docx

Use the new ratio parameter for dynamic y-scaling of 1D spectra. 
Left spectrum has a fit = 90%, right = 10%

What’s New

We are delighted to release our new version of PhysChem Suite™, Version 2026.

Highlighted Features

  • Improved hydrogen bond calculations
  • Interactive physicochemical property visualization
  • Custom compound names in prediction reports

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

Further Details

Version 2026 introduces more chemically accurate property calculations, interactive visualization of calculated properties, and greater flexibility when generating prediction reports.

Algorithm Improvements

Improved Hydrogen Bond Calculations

You can now expect more chemically accurate hydrogen bond donor and acceptor calculations.

Improvements include:

  • Hydrogen bond donor and acceptor calculations now use chemically aware definitions rather than simple nitrogen and oxygen atom counts.
  • Sulfur atoms are now recognized as hydrogen bonding sites where appropriate.
  • Nitrogen atoms with inaccessible electron pairs, such as pyrroles and nitro groups, are no longer counted as hydrogen bond acceptors.

Ease of Use

Interactive Physicochemical Property Visualization

You can now interact with selected calculated properties to highlight and visualize the atoms or bonds contributing to each property.

Image 1 from WN PhysChem Suite v2026.docx

Interactive highlighting is available for the following:

  • Number of Hydrogen bond donors
  • Number of Hydrogen bond acceptors
  • Number of Rotatable bonds
  • Number of Rings (also differentiated by ring size)
  • Number of Aromatic rings

Highlight the contributions of different atoms or bonds.

Reporting

Custom Compound Names in Prediction Reports

You can now customize compound names in PDF and Word prediction reports, providing greater flexibility in report preparation. Override automatically assigned names or add names when none are available.

Features include:

  • Override automatically assigned compound names with your preferred name or synonym.
  • Add custom names for compounds that cannot be automatically identified.
  • Enter custom names when generating single-compound reports.
  • Select a spreadsheet column as the source of compound names when generating batch reports.

Percepta Portal

More Flexible Project Import and Merging

You can now combine data from multiple Spreadsheet projects more efficiently while maintaining existing project structures. New import and merge options give you greater control over how compounds, data fields, and duplicate information are matched, helping reduce manual data management when consolidating projects.

  • Link matching columns between projects to populate existing fields instead of creating duplicates.
  • Merge projects by matching data fields or chemical structures, with configurable structure matching criteria.
  • Control how conflicting or unmatched data is handled and preview merge results before importing.

Note: Existing projects created in earlier software versions must be upgraded to generate the structure metadata required for structure-based project merging.

Greater Control Over User and Project Management

You can now manage users, projects, and permissions with greater flexibility across your organization. Expanded authentication, permission, and account management capabilities make it easier to administer shared environments while giving users greater visibility of the projects and resources available to them.

  • Configure multiple OpenID providers and automatically assign users to groups based on their authentication method.
  • Manage user access more effectively with suspended accounts and more granular permissions.
  • Find projects more easily by owner and see how workspace licenses are assigned through user groups.
  • Give regular users greater control over their own account information and visibility of shared projects, group memberships, and licensed workspaces.

Ease of Use

You can now complete everyday tasks more efficiently with a range of workflow improvements throughout Percepta Portal. Updates to reporting, spreadsheet editing, and molecular input and output tools help streamline routine activities and reduce the risk of errors.

  • Identify expression elements and syntax errors more easily with syntax highlighting in the Expression Editor.
  • Avoid unintended deletion of dependent calculations with additional warnings.
  • Generate PDF reports for all compounds in a project using batch reporting.
  • Copy molecular structures as SMILES or exchange structures using InChI notation.

Simplified Deployment and Administration

You can now deploy and maintain Percepta Portal more easily with updates designed to improve compatibility, reduce deployment dependencies, and simplify software administration.

  • Improved startup health checks simplify deployment and container management.
  • Automatic compatibility checks help prevent issues caused by incompatible MongoDB or Percepta Kernel versions.
  • Updated framework components provide improved Java 17 support.

What’s New

We are delighted to release our new version of Percepta® Suite, Version 2026.

Highlighted Features

  • New P-gp IC50 prediction module.
  • Enhanced Ames test predictor.

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

Further Details

Version 2026 introduces a new quantitative P-gp IC50 prediction module, improved Ames Test prediction accuracy, and enhancements to core PhysChem functionality.

Algorithm Improvements

New P-gp IC50 Prediction Module

You can now predict P-glycoprotein inhibition potency using a dedicated P-gp IC50 module to support ADME evaluation in addition to predicting quantitative efflux ratios (implemented in V2025).

The rule-based P-gp inhibition model has been replaced by a dedicated P-gp IC50 submodule with the following features:

  • Predictions are based on key physicochemical and topological parameters and returned in quantitative half-inhibitory constants (IC50).
  • Editable text boxes displaying predicted descriptor values, with the option to manually enter experimental values to refine predictions or explore the effect of property changes on inhibitory potency.
  • Similar structure listing shows experimental IC50 values, inhibitor/non-inhibitor classification, assay type, and references.
Image 1 from WN Percepta Suite v2026.docx

Predict P-gp IC50 values and view experimental IC50 values for similar structures.

Enhanced Ames Test Predictor

You can now expect greater accuracy of the Bacterial Composite (Procaryote Mutagenicity) predictor. Improvements include:

Image 2 from WN Percepta Suite v2026.docx
  • Significant expansion with experimental data for ~7000 new compounds (64% increase in database size).
  • Integration of data from a large comparative study combining multiple public genotoxicity databases.
  • Additional curation of experimental results to resolve conflicting data from different sources.

Improved Hydrogen Bond Calculations

You can now expect more chemically accurate hydrogen bond donor and acceptor calculations.

Improvements include:

  • Hydrogen bond donor and acceptor calculations now use chemically aware definitions rather than simple nitrogen and oxygen atom counts.
  • Sulfur atoms are now recognized as hydrogen bonding sites where appropriate.
  • Nitrogen atoms with inaccessible electron pairs, such as pyrroles and nitro groups, are no longer counted as hydrogen bond acceptors.

Ease of Use

Interactive Physicochemical Property Visualization

You can now interact with selected calculated properties to highlight and visualize the atoms or bonds contributing to each property.

Image 3 from WN Percepta Suite v2026.docx

Interactive highlighting is available for the following:

  • Number of Hydrogen bond donors
  • Number of Hydrogen bond acceptors
  • Number of Rotatable bonds
  • Number of Rings (also differentiated by ring size)
  • Number of Aromatic rings

Highlight the contributions of different atoms or bonds.

Reporting

Custom Compound Names in Prediction Reports

You can now customize compound names in PDF and Word prediction reports, providing greater flexibility in report preparation. Override automatically assigned names or add names when none are available.

Features include:

  • Override automatically assigned compound names with your preferred name or synonym.
  • Add custom names for compounds that cannot be automatically identified.
  • Enter custom names when generating single-compound reports.
  • Select a spreadsheet column as the source of compound names when generating batch reports.

Percepta Portal

More Flexible Project Import and Merging

You can now combine data from multiple Spreadsheet projects more efficiently while maintaining existing project structures. New import and merge options give you greater control over how compounds, data fields, and duplicate information are matched, helping reduce manual data management when consolidating projects.

  • Link matching columns between projects to populate existing fields instead of creating duplicates.
  • Merge projects by matching data fields or chemical structures, with configurable structure matching criteria.
  • Control how conflicting or unmatched data is handled and preview merge results before importing.

Note: Existing projects created in earlier software versions must be upgraded to generate the structure metadata required for structure-based project merging.

Greater Control Over User and Project Management

You can now manage users, projects, and permissions with greater flexibility across your organization. Expanded authentication, permission, and account management capabilities make it easier to administer shared environments while giving users greater visibility of the projects and resources available to them.

  • Configure multiple OpenID providers and automatically assign users to groups based on their authentication method.
  • Manage user access more effectively with suspended accounts and more granular permissions.
  • Find projects more easily by owner and see how workspace licenses are assigned through user groups.
  • Give regular users greater control over their own account information and visibility of shared projects, group memberships, and licensed workspaces.

Ease of Use

You can now complete everyday tasks more efficiently with a range of workflow improvements throughout Percepta Portal. Updates to reporting, spreadsheet editing, and molecular input and output tools help streamline routine activities and reduce the risk of errors.

  • Identify expression elements and syntax errors more easily with syntax highlighting in the Expression Editor.
  • Avoid unintended deletion of dependent calculations with additional warnings.
  • Generate PDF reports for all compounds in a project using batch reporting.
  • Copy molecular structures as SMILES or exchange structures using InChI notation.

Simplified Deployment and Administration

You can now deploy and maintain Percepta Portal more easily with updates designed to improve compatibility, reduce deployment dependencies, and simplify software administration.

  • Improved startup health checks simplify deployment and container management.
  • Automatic compatibility checks help prevent issues caused by incompatible MongoDB or Percepta Kernel versions.
  • Updated framework components provide improved Java 17 support.

What’s New

We are delighted to release our new version of Impurity Profiling Suite ™, Version 2026.

Highlighted Features

  • Enhanced Ames test predictor.
  • Streamlined ICH M7 classification.

  • Improved CPCA categorization of N-Nitrosamines.

Administrators are recommended to subscribe to the channels within our support news site found at https://support.revvitysignals.com/hc/en-us/categories/360004446171-Support-News which contains more information about releases and other pertinent product information.

Further Details

Version 2026 introduces improvements to ICH M7 classification workflows, enhanced N-nitrosamine CPCA categorization, expanded literature references, and a major update to the Ames Test predictor training library.

Algorithm Improvements

Enhanced Ames Test Predictor

You can now expect greater accuracy of the Bacterial Composite (Procaryote Mutagenicity) predictor.

Image 1 from WN Impurity Profiling Suite v2026.docx

Improvements include:

  • Significant expansion with experimental data for ~7000 new compounds (64% increase in database size).
  • Integration of data from a large comparative study combining multiple public genotoxicity databases.
  • Additional curation of experimental results to resolve conflicting data from different sources.

Classification

Streamlined ICH M7 Classification

  • You can now perform ICH M7 assessments more efficiently with clearer classification outputs, improved reporting, and enhanced handling of parent-derivative analyses. You can expect greater transparency and simplified interpretation of ICH M7 results.
  • Key improvements include:
    • ICH M7 calculations in Spreadsheet now include an additional Ames test field displaying the final mutagenicity prediction (Positive, Negative, or Undefined) in a simple text format.
    • In parent-derivative analyses, the parent molecule is now clearly identified as the API, reducing ambiguity and ensuring it is evaluated independently from its derivatives.
    • Compounds with inconclusive predictions are now assigned Class 3 rather than returning a numerical value of "0", helping ensure potentially relevant compounds receive appropriate attention while clearly indicating when expert review may change the outcome.
    • PDF reports now include more detailed explanations of classification comments to support interpretation and decision making.
    • Experimental Ames negative data can now take precedence over positive findings in other endpoints, enabling Class 5 assignments where appropriate.
Image 2 from WN Impurity Profiling Suite v2026.docx

Experimental Ames negative data enables Class 5 assignments where appropriate.

Improved CPCA categorization of N-Nitrosamines

  • You can expect better alignment of Impurity Profiling Suite results with publicly available FDA reference data when assessing N-nitrosamine impurities. The CPCA categorization algorithm for N-nitrosamines has been revised to more closely match the methodology used to generate FDA-published CPCA scores and category assignments.*

* Minor differences may still occur due to differences in tautomer handling and software architecture.

Ease of Use

Additional Reference Information for Supporting Data

You can now view the references for supporting experimental data sources directly in the Impurity Profiling module interface and ICH M7 classification reports for:

  • Similar structure listing for Ames Test.
  • TD50 listings for Rat Composite and Mouse Composite Carcinogenicity, which now also indicate when data has been obtained from the Carcinogenic Potency Database (CPDB).